Maximum Frame Shift
This is the maximum amount in image pixels that the algorithm will shift the frame horizontally
and vertically in either direction from the normal position. Both horizontal and vertical shifts
are settable in the range [24 256], the default is 128.
Usually the only reason to select low Frame Shift values is when the Border In-Fill is in Fixed
mode because as the borders are increased in size the viewable image area gets smaller by the
same amount.
Note
i
Setting these values too low will prevent the algorithm from stabilizing properly.
The lower the setting the less stabilization range is possible.