1. Check the ‘Enable LED’ box to enables the LED function.
2. Select the ‘Event Publisher’ you want to apply for the LED1 / LED2.
3. Select the ‘Operation Type’ of each LED, Blink or On mode.
4. Select the ‘Time Out,’ among 1 ~ 5 sec or permanent alarming.
Location of LED
In case of 1 channel encoder for H.264, you can find that there are 2 LEDs on the left side of
the video input port. Each of the products has different position of LEDs and you should refer
to the ‘Hardware Installation guide’ of your model (Refer to the \DOC of your SDK).
The option page provides the configuration of DSP load, temperature change, and video loss.
(1) Set the dspload limits to
E.g. Setting the value as 90% - While the DSP load keeps lower than 90%, the LED will operate
as you configured at Location tab.
(2) Set the temperature limits to
E.g. Setting the min 0 and max 65 - While the temperature is between 0 and 65, the LED will
operate as you configured at Location tab.
(3) Turn on the LED of Vsignal
Select one of the options between ‘When video signal loss is detected’ and ‘When video signal
is normal.’ Then, the selected LED will operate when the selected condition is satisfied.
(4) Turn on the LED of Heartbeat
Select one of the options between ‘When heartbeat status is watchdog’ and ‘When heartbeat
status is normal.’ Then, the selected LED will operate when the selected condition is satisfied.
For more details about the publisher’s triggers condition, refer to the ‘EAD-series
Event System Manual.pdf’. It describes the threshold for event triggering, event
message format, and triggering condition etc.